Victron Energy · Inverter/charger

Victron MultiPlus, MultiPlus Compact & MultiPlus-II

The MultiPlus is Victron Energy’s inverter/charger: a sine-wave inverter with a mains-frequency transformer, an adaptive battery charger and an automatic transfer switch in one case, so the boat’s 230 V circuits run on shore power or the generator and switch to the batteries in under 20 ms when that supply drops. Three lines are around: the classic MultiPlus (500 VA to 5 kVA at 12, 24 or 48 V, including the steel-cased 2 kVA), the MultiPlus Compact (800 to 2000 VA, 12 or 24 V, aluminium case, the small sizes with battery cables fitted at the factory) and, since 2018, the MultiPlus-II (3 to 15 kVA), whose GX versions add a built-in GX device with display, Wi-Fi and Ethernet. The model code reads battery voltage / inverter VA / charge current – transfer-switch current: a 12/3000/120-50 is a 12 V, 3000 VA unit with a 120 A charger and a 50 A transfer switch. All of them talk VE.Bus over RJ45 cables, so the temperature sensor, the MK3-USB interface, the Digital Multi Control panel and the network cables fit the whole range; what changes from model to model is the DC fuse, the battery cable size and the AC input breaker. Besides the 230 V units listed here, Victron builds 120 V versions with their own manuals.

  • Manuals & documents
  • Wear parts & part numbers
  • Service intervals
  • Specifications
  • Good to know
  • Videos & how-tos
  • On the marketplace

Manuals & documents

The links go straight to Victron Energy. We host no manuals or drawings — the manufacturer’s copy is the current one.

  • MultiPlus-II 230V manual: 3000, 5000, 8000, 10000 and 15000 VA (rev 14, 2026) Operation manual victronenergy.com · PDF · EN · DE · FR · ES
  • MultiPlus-II 4k, 4k5, 6k5, 10k 230V manual (rev 05, 2026) Operation manual victronenergy.com · PDF · EN · DE · FR · ES
  • MultiPlus-II GX manual (rev 13, 2026) Operation manual victronenergy.com · PDF · EN · DE · FR · ES
  • MultiPlus 2kVA 230V manual: 12/2000/80, 24/2000/50, 48/2000/25 (rev 08, 2025) Operation manual victronenergy.com · PDF · EN · DE · FR · ES
  • MultiPlus 12, 24, 48 V / 3000 VA, 16 A and 50 A, firmware xxxx4xx: manual Operation manual victronenergy.com · PDF · EN · NL · FR · DE · ES · SV
  • MultiPlus 24/5000/120 and 48/5000/70, 100 A, firmware xxxx4xx: manual Operation manual victronenergy.com · PDF · EN · NL · FR · DE · ES · SV
  • MultiPlus 500 VA – 1200 VA manual (12, 24, 48 V) Operation manual victronenergy.com · PDF · EN · NL · FR · DE · ES · IT
  • MultiPlus 1600 VA manual (12, 24, 48 V) Operation manual victronenergy.com · PDF · EN · NL · FR · DE · ES · IT
  • MultiPlus Compact 800, 1200, 1600 VA manual (12 and 24 V) Operation manual victronenergy.com · PDF · EN · NL · FR · DE · ES
  • MultiPlus Compact 2000 VA manual (12/2000/80 and 24/2000/50) Operation manual victronenergy.com · PDF · EN · NL · FR · DE · ES
  • MultiPlus-II 230V datasheet (3000 to 15000 VA) Spec sheet victronenergy.com · PDF · EN · DE · FR · ES
  • MultiPlus-II GX datasheet (24/3000, 48/3000, 48/5000) Spec sheet victronenergy.com · PDF · EN · DE · FR · ES
  • MultiPlus 800 VA – 5 kVA datasheet, including the MultiPlus Compact Spec sheet victronenergy.com · PDF · EN · DE · FR · ES
  • VictronConnect configuration guide for VE.Bus products (settings, limitations, firmware updates) Software update victronenergy.com · HTML · EN · DE · FR · ES
  • System schematic: monohull with MultiPlus, Lynx Smart BMS NG and lithium bank, no generator Wiring diagram victronenergy.com · PDF · EN
  • System schematic: catamaran with two MultiPlus 5kVA/24V in parallel, lithium bank, no generator Wiring diagram victronenergy.com · PDF · EN
  • MultiPlus-II: models, article numbers, all downloads Product page victronenergy.com · HTML · EN
  • MultiPlus 800 VA – 3 kVA and MultiPlus Compact: models, article numbers, downloads Product page victronenergy.com · HTML · EN
  • Victron Community: questions and answers from installers and owners Manual portal community.victronenergy.com · HTML · EN

Wear parts & part numbers

PartOEM numberAlso fitsNote
Temperature sensorASS0000010001,2,3,4,5—Battery temperature sensor for every MultiPlus, Compact and MultiPlus-II (it also fits GX devices). Supplied with the 12 and 24 V units, not with the 48 V MultiPlus-II and MultiPlus-II GX. Mount it on the battery minus pole. If charging drops to zero at absorption with a cool battery, unplug the sensor, switch the unit off, wait 4 seconds and on again: if it now charges normally, the sensor is faulty.
Data converter / gatewayASS030140000 · ASS0301400306,4,7,8—Interface MK3-USB (ASS030140000) or MK3-USB-C (ASS030140030), VE.Bus to USB: needed to change settings and update firmware on any MultiPlus with VictronConnect or VEConfigure; plugs into a VE.Bus socket with an RJ45 cable. VictronConnect does not work with the older MK2-USB.
Bluetooth dongleASS0305370109,4,7—VE.Bus Smart dongle: Bluetooth link to VictronConnect for every MultiPlus, Compact and MultiPlus-II — shows status and alarms, switches On, Off and Charger only and sets the shore current limit; it also measures battery voltage and temperature for the charger. It cannot change settings or update firmware: that needs the MK3-USB.
Remote controlDMC000200010R · REC02000501010,11,4,12—Digital Multi Control 200/200A GX (DMC000200010R, right-angle RJ45) or Digital Multi Control 200/200A (REC020005010): panel with On/Off/Charger-only switch and a knob for the shore or generator current limit (PowerControl/PowerAssist, up to 200 A), for every MultiPlus including parallel and three-phase systems; connects with an RJ45 cable. Only one remote — panel or switch — per system.
Network cableASS030064921 · ASS030064951 · ASS030064981 · ASS030065001 · ASS03006501113,4replaces ASS030064920replaces ASS030064950replaces ASS030064980replaces ASS030065000replaces ASS030065010—RJ45 UTP cable for VE.Bus: panel, MK3-USB, GX device and the links between parallel or three-phase units. Lengths in order: 0.9 m, 1.8 m, 3 m, 5 m, 10 m (also 0.3, 15, 20 and 30 m). Victron has renumbered them; the older numbers in the same order are listed as replaced.
Network connector (T-piece, terminator)ASS03006551114,4,15,12replaces ASS030065510—RJ45 splitter (1× RJ45 male on a 15 cm cable, 2× RJ45 female): Victron’s part for parallel and three-phase systems of the MultiPlus 500–1600 VA. On the MultiPlus 3000 VA, by contrast, the manual forbids splitters and connection boxes — the cables run unit to unit.
CableASS03055012016,4—Inverting remote on-off cable: connects the remote on/off input of a MultiPlus to a VE.Bus BMS or to the load output of a BlueSolar MPPT, so the inverter switches off when the battery is empty; with a VE.Bus BMS a second cable can switch off the charger as well.
Battery management system (BMS)BMS30020020017,18replaces BMS300200000—VE.Bus BMS V2: protects Victron Lithium Battery Smart 12.8 V and 25.6 V in a system with a VE.Bus inverter/charger and switches inverter and charger via VE.Bus; the MultiPlus-II manual names it (or the Lynx Smart BMS) for these batteries.
Battery management system (BMS)BMS30020030019—VE.Bus BMS NG: the counterpart for Victron Lithium NG batteries with VE.Bus inverter/chargers, with Bluetooth built in. Not compatible with Lithium Battery Smart — check which battery series is on board.
Current sensor / transformerCTR110000500 · CTR110000550 · CTR110002050 · CTR120000500 · CTR120000550 · CTR120002050 · CTR14005010020,4,18—MultiPlus-II only: external current transformer 100 A:50 mA for PowerControl and PowerAssist when loads are wired ahead of the inverter, and for self-consumption systems. With jack plug 1 m / 5 m / 20 m (CTR110000500 / CTR110000550 / CTR110002050), with wire ends CTR120000500 / CTR120000550 / CTR120002050; 400 A:50 mA with 10 m wire ends CTR140050100.
FuseCIP138100020 · CIP138125020 · CIP138200020 · CIP138250020 · CIP138300020 · CIP138400020 · CIP13640001021,4,18,22,12,23,5,24replaces CIP136100010replaces CIP136125010replaces CIP137125010replaces CIP136200010replaces CIP137200010replaces CIP136250010replaces CIP137250010replaces CIP136300010replaces CIP137300010—Victron MEGA fuses (80 V ceramic, pack of 5) in the DC fuse ratings the manuals give: 100 A CIP138100020 (48/2000); 125 A CIP138125020 (48/3000, MultiPlus-II 48/3000); 200 A CIP138200020 (24/2000, Compact 24/2000, 48/5000, MultiPlus-II 48/5000); 250 A CIP138250020 (MultiPlus-II 48/6k5); 300 A CIP138300020 (12/2000, Compact 12/2000, 24/3000, MultiPlus-II 24/3000 and 48/8000); 400 A CIP138400020 or 400 A/32 V CIP136400010 for 12 and 24 V (12/3000, 24/5000, MultiPlus-II 12/3000, 24/5000, 48/10k). Victron lists no 600 A MEGA fuse for the MultiPlus-II 12/4k, 12/5000 and 48/15000. The 32 V and 58 V versions are replaced by the 80 V ones.
Fuse holder / fuse baseCIP000100001 · CIP10020010021,4—Victron holders for the MEGA fuses above: single holder CIP000100001 or modular holder CIP100200100 (can be joined with a busbar).
Isolation transformerITR040252043 · ITR040452042 · ITR050452042 · ITR00080200225,4,18,12replaces ITR040202041replaces ITR040252042replaces ITR040362041replaces ITR040362042replaces ITR050362041replaces ITR050362042replaces ITR000702001replaces ITR000702002—Every MultiPlus manual advises against connecting the shore earth straight to the boat because of galvanic corrosion and names an isolation transformer as the solution. Victron’s units with soft start: 2500 W 115/230 V ITR040252043, 4500 W 115/230 V ITR040452042, 4500 W auto 115/230 V ITR050452042, 8000 W 230 V ITR000802002; the replaced numbers belong to the earlier 2000/2500 W, 3600 W and 7000 W versions.

Numbers checked against the sources below on 23 October 2026. Always confirm against your serial number and exact type before ordering.

Service intervals

TaskInterval
Electrical connectionsOnce a year: check all connections — battery nuts (M8, 12 Nm), AC terminals and VE.Bus plugs. This is the only interval in the manuals of the MultiPlus 500–1600 VA, Compact, 3000/5000 VA, MultiPlus-II and MultiPlus-II GX; the 2 kVA manual names none18,26,12,23,15,27,28,24,5
Full serviceOngoing: keep the unit clean and dry, away from moisture, oil, soot and vapour, vents free. No user-serviceable parts inside; on the MultiPlus-II the internal fuses are not user-replaceable either18,5,12
Battery charging & storageLead-acid traction batteries only, when the battery maker asks for it: equalise for one hour at 1 V (12 V), 2 V (24 V) or 4 V (48 V) above absorption voltage, started from the front switch or the panel once the charger is in float; disconnect DC loads first18
Software updateOnly when needed: at commissioning, to fix a problem or for a feature the installation requires — Victron says stable systems should stay on their firmware. Every update resets all settings, Assistants and parallel or three-phase set-up to factory defaults, so save the configuration first29,30
Storage / winterisingBefore laying up or transporting: disconnect the mains supply and the battery leads; store dry at −20 to +60 °C (MultiPlus-II) or −40 to +70 °C (2 kVA)18,5

Victron gives no running hours or service schedule for the MultiPlus family. The manuals ask for one thing — check all connections once a year — and otherwise rely on a clean, dry, ventilated place; firmware is updated only when there is a reason.

Specifications

TypeInverter/charger with a mains-frequency isolating transformer: true sine-wave inverter, adaptive four-stage charger (bulk, absorption, float, storage) and automatic transfer switch in one case. Takes over the loads in under 20 ms when shore or generator power fails; up to 6 identical units in parallel, three units for three-phase8,2,18,5,31
VersionsMultiPlus 500–1600 VA: steel/ABS case, IP21, 16 A transfer switch, parallel and three-phase via an RJ45 splitter; the 500 VA has PowerControl but no PowerAssist. MultiPlus Compact 800–2000 VA: aluminium case, 12 and 24 V only, G-ST18i AC plug (2000 VA: spring-clamp terminals). MultiPlus 2 kVA: steel case, 32 A transfer switch, no internal DC fuse. MultiPlus 3000/5000 VA: aluminium case, IP20, second AC output. Classic MultiPlus and Compact also take basic settings by DIP switch. MultiPlus-II: flatter steel case, built-in anti-islanding for grid feed-in (ESS), optional external current transformer, set up by software only; GX versions with display, Wi-Fi, Ethernet, USB, VE.Direct and a BMS-Can port15,27,28,24,5,12,18,8,2,3,31
ModelsMultiPlus 500–1600 VA (230 V): 12/500/20-16 PMP121500000, 24/500/10-16 PMP241500000, 48/500/6-16 PMP481500000; 12/800/35-16 PMP121800000, 24/800/16-16 PMP241800000, 48/800/9-16 PMP481800000; 12/1200/50-16 PMP122120000, 24/1200/25-16 PMP242120000, 48/1200/13-16 PMP482120000; 12/1600/70-16 PMP122160000, 24/1600/40-16 PMP242160000, 48/1600/20-16 PMP48216000032,4
ModelsMultiPlus Compact (230 V): C 12/800/35-16 CMP121800000, C 12/1200/50-16 CMP122120000, C 12/1600/70-16 CMP122160000, C 24/1600/40-16 CMP242160000, C 12/2000/80-30 CMP122200000, C 24/2000/50-30 CMP242200000. MultiPlus 2000 VA: 12/2000/80-32 PMP122200000, 24/2000/50-32 PMP242200000, 48/2000/25-32 PMP482200000; newer 2 kW models 12/2k/100-32 PMP122200010 and 48/2k/30-32 PMP48220001033,34,4,35
ModelsMultiPlus 3000/5000 VA (230 V): 12/3000/120-16 PMP122300001, 12/3000/120-50 PMP123021010 (newer number PMP122301013), 24/3000/70-16 PMP242300001 (newer PMP242300003), 24/3000/70-50 PMP242301011, 48/3000/35-16 PMP482300000 (earlier PMP483020001), 48/3000/35-50 PMP483021010, 24/5000/120-100 PMP245021010, 48/5000/70-100 PMP48502101033,4
ModelsMultiPlus-II (230 V): 12/3000/120-32 PMP122305010, 24/3000/70-32 PMP242305010, 48/3000/35-32 PMP482305012 (earlier PMP482305010), 12/4k/160-32 PMP122405010, 48/4k5/55-32 PMP482405012, 12/5000/220-50 PMP122505012 (earlier PMP122505010), 24/5000/120-50 PMP242505010, 48/5000/70-50 PMP482505012 (earlier PMP482505010), 48/6k5/100-50 PMP482605012, 48/8000/110-100 PMP482805000, 48/10000/140-100 PMP483105000, 48/10k/150-100 PMP483105020, 48/15000/200-100 PMP483150000. GX versions: 24/3000/70-32 GX PMP242306002 (earlier PMP242306000), 48/3000/35-32 GX PMP482306000, 48/4k5/55-32 GX PMP482406000, 48/5000/70-50 GX PMP482506020 (earlier PMP482506000), 48/6k5/100-50 GX PMP48260600036,37,4
VoltageBattery input 9.5–17 V (12 V models), 19–33 V (24 V), 38–66 V (48 V; MultiPlus-II 48/4k5 and 48/6k5 38–60 V, 48/10k/150 40–66 V). AC output 230 V ± 2 %, 50 Hz ± 0.1 % (60 Hz selectable). Charger AC input 187–265 V, 45–65 Hz8,2,38,22
VoltageDefault charge voltages for 12 / 24 / 48 V: absorption 14.4 / 28.8 / 57.6 V, float 13.8 / 27.6 / 55.2 V, storage 13.2 / 26.4 / 52.8 V. Storage mode starts after 24 h without discharge and lifts the battery back to absorption once a week; temperature compensation via the battery sensor8,2,5
OutputMultiPlus and Compact, continuous at 25 °C / peak: 500 VA 430 / 900 W; 800 VA 700 / 1600 W; 1200 VA 1000 / 2400 W; 1600 VA 1300 / 2800 W (Compact 3000 W); 2000 VA 1600 / 3500 W (Compact 24 V 4000 W; new 2 kW models 2000 / 4000 W); 3000 VA 2400 / 6000 W; 5000 VA 4000 / 10000 W. Heat cuts the continuous rating, e.g. 3000 VA: 2200 W at 40 °C, 1700 W at 65 °C. Max. efficiency 90–95 %15,27,28,24,5,35,8
OutputMultiPlus-II, continuous at 25 °C / peak: 3000 VA 2400 / 5500 W; 12/4k 3400 W / 6 kW briefly; 48/4k5 4000 W / 7 kW for 1 min; 5000 VA 4000 / 9000 W; 48/6k5 6000 W / 11 kW for 1 min; 8000 VA 6400 / 15000 W; 10000 VA 8000 / 18000 W (10k/150: 10000 W / 15 kW for 2 min); 15000 VA 12000 / 27000 W. Max. efficiency 93–96 %2,38,18,22
Charge currentHouse battery at 25 °C, 12 / 24 / 48 V: 500 VA 20 / 10 / 6 A; 800 VA 35 / 16 / 9 A; 1200 VA 50 / 25 / 13 A; 1600 VA 70 / 40 / 20 A; Compact 2000 80 / 50 A; 2000 VA 80 / 50 / 25 A (2 kW: 100 / 60 / 30 A); 3000 VA 120 / 70 / 35 A; 5000 VA 120 A (24 V), 70 A (48 V). MultiPlus-II: 3000 VA 120 / 70 / 35 A, 12/4k 160 A, 48/4k5 55 A, 5000 VA 220 / 120 / 70 A, 48/6k5 100 A, 8k 110 A, 10k 140 A (10k/150: 150 A), 15k 200 A. Starter-battery output (12 and 24 V only): 1 A on the 500–2000 VA MultiPlus, 4 A on the Compact, the 3000/5000 VA and the MultiPlus-II15,27,28,24,5,35,8,2,38,18
Transfer switch16 A: MultiPlus 500–1600 VA, Compact 800–1600 and MultiPlus 3000 “-16”; 30 A: Compact 2000; 32 A: MultiPlus 2 kVA and MultiPlus-II 3000, 12/4k, 48/4k5; 50 A: MultiPlus 3000 “-50”, MultiPlus-II 5000 and 48/6k5; 100 A: MultiPlus 5000 and MultiPlus-II 8k to 15k. Changeover in under 20 ms. Second output AC-out-2 (3000 VA and up): drops at once in inverter mode, comes back about 2 minutes after AC returns — for water heater or air conditioning8,2,38,5,24,12,18
Power consumptionStandby with no load (normal / AES / search mode): MultiPlus 500 VA 6–7 W (search 2–3 W); 2 kVA 10–11 W (search 3–4 W); 3000 VA 20–25 / 15–20 / 8–12 W; 5000 VA 30–35 / 25–30 / 10–15 W. MultiPlus-II 3000 VA 11–13 / 7–9 / 2–3 W; 5000 VA 15–18 / 11–12 / 2–3 W; 15 kVA 55 / 39 / 6 W15,5,8,2
Power cable sizeMultiPlus and Compact, battery cable per + and − terminal for 0–5 m and DC fuse: 12/2000 70 mm², 300 A; 24/2000 35 mm², 200 A; 48/2000 25 mm², 100 A (Compact 12/2000 and 24/2000 the same as the 12 and 24 V 2000 VA); 12/3000 2× 50 mm², 400 A; 24/3000 50 mm², 300 A; 48/3000 35 mm², 125 A; 24/5000 2× 50 mm², 400 A; 48/5000 70 mm², 200 A. For 1.5–5 m on the small units: 500/800/1200/1600 VA 16/25/35/50 mm² at 12 V; Compact 12 V 800/1200/1600 35/50/70 mm² (factory cables 1.5 m). Their manuals give no external DC fuse rating (the 500–1200 VA manual lists the internal fuses instead), yet the safety chapter asks for fused DC cables. Longer runs (5–10 m): the next size in the manual’s table5,24,12,23,15,27,28
Power cable sizeMultiPlus-II, battery cable per + and − terminal for 0–5 m and DC fuse: 12/3000 2× 50 mm², 400 A; 24/3000 50 mm², 300 A; 48/3000 35 mm², 125 A; 12/4k 2× 70 mm², 600 A; 48/4k5 50 mm², 180 A; 12/5000 2× 95 mm², 600 A; 24/5000 2× 50 mm², 400 A; 48/5000 70 mm², 200 A; 48/6k5 70 mm², 250 A; 48/8000 2× 50 mm², 300 A; 48/10000 and 48/10k/150 2× 50 mm², 400 A; 48/15000 2× 95 mm², 600 A. “2×” means two positive and two negative cables; copper rated 90 °C, not in a closed conduit; M8 battery nuts at 12 Nm18,22
Breaker / fuseAC input fuse or breaker at most: 16 A on the MultiPlus 3000 “-16”, 30 A on the Compact 2000, 32 A on the 2 kVA and the MultiPlus-II 3000/4k/4k5, 50 A on the MultiPlus 3000 “-50” and MultiPlus-II 5000/6k5, 100 A on the MultiPlus 5000 and MultiPlus-II 8k–15k; a weaker shore supply needs a correspondingly smaller one. The Compact 800–1600 has a resettable 16 A thermal breaker built in. AC output: an RCD plus a breaker sized for the load (MultiPlus 3000: max. 32 A on “-16”, 63 A on “-50”; Compact 2000: max. 40 A)12,23,5,24,28,18,2,38
Data connectionsVE.Bus (RJ45; two sockets on the MultiPlus 3000 VA and the MultiPlus-II) for panels, GX devices, MK3-USB and parallel or three-phase links; remote on/off terminal; programmable relay (230 V / 4 A AC, 4 A up to 35 V DC); battery temperature sensor; voltage sense on the 3000 VA and MultiPlus-II; programmable analogue/digital ports (MultiPlus 3000: one on “-16”, two on “-50”; MultiPlus-II: two). MultiPlus-II: input for the external current transformer. MultiPlus-II GX also BMS-Can, USB, Ethernet, VE.Direct and Wi-Fi12,18,2,3
SoftwareVE.Bus firmware: a seven-digit number on a sticker (e.g. 2654153) — 26 or 27 at the start means the newer microprocessor (230 V / 120 V), 19 or 20 the old one. Firmware 4xx combines Virtual Switch and Assistants and runs only on the newer processor. Set-up with VictronConnect (MK3-USB; full access from firmware 415) or VEConfigure; Assistants such as ESS, grid codes, the lithium wizard and the external current sensor still need VEConfigure39,7,30
Waterproof ratingIP20: MultiPlus 3000/5000 VA (aluminium). IP21: MultiPlus 500–2000 VA (steel/ABS), Compact (aluminium) and the newer MultiPlus-II 12/4k, 48/4k5, 48/6k5, 48/10k/150. IP22: MultiPlus-II 3k–15k and GX (steel). Only for a dry, dust-free, well-ventilated place12,15,5,28,38,2,3,18
WeightMultiPlus 500/800/1200/1600 VA 4.4/6.4/8.2/10 kg; Compact 800–1600 10 kg, Compact 2000 12 kg; 2 kVA 15.5 kg; 3000 VA 18–19 kg; 5000 VA 30 kg. MultiPlus-II 3000 VA 19–20 kg; 12/4k and 48/4k5 22 kg; 5000 VA 30–33 kg; 48/6k5 29 kg; 8k 42 kg; 10k 49 kg; 15k 80 kg; GX 3000 VA 20 kg, 5000 VA 31 kg15,27,8,5,12,2,18,38,3
Operating temperature−40 to +65 °C with fan-assisted cooling, humidity up to 95 % non-condensing, up to 2000 m. Allow at least 10 cm of free space around the unit; above 25 °C the continuous output and the charge current drop8,2,5,15
Years builtMultiPlus-II presented in May 2018 with the 48/3000/35-32, as a redesign with a flatter steel case and less than half the standby draw of the unit it replaced; classic MultiPlus, MultiPlus Compact and MultiPlus-II are all in Victron’s 2026 price list31,4
Warranty5 years standard warranty from Victron, with repair service through the original dealer36

Good to know

  • Before buying a used unit, find the seven-digit firmware number on the sticker on the control board. A number starting 26 or 27 means the newer microprocessor: it takes current 4xx firmware and, from version 415, can be fully set up with VictronConnect. A number starting 19 or 20 is the old microprocessor: VictronConnect can only read it, settings and updates then need VEConfigure and VEFlash.7,39,30
  • A firmware update returns the unit to factory settings, including Assistants and any parallel or three-phase configuration — save the settings first. In parallel and three-phase systems every unit must be the same model on the same firmware; the MultiPlus-II 8k, 10k and 15k can only run in parallel with an external transfer switch.29,39,12,2
  • The VE.Bus Smart dongle is enough for watching the unit and switching it from the phone, but not for changing settings or updating firmware: that takes an MK3-USB on a computer or an Android device with a USB port — not an iPhone or iPad.7,9
  • On board, the MultiPlus links neutral to earth itself when no shore power is present (ground relay), so the RCD on its output keeps working. Bond the case to the hull or grounding plate (MultiPlus-II: at least 4 mm²) and do not run the shore earth straight into the boat: Victron recommends an isolation transformer against galvanic corrosion.18,12,27
  • Mount it in a dry, ventilated compartment close to the batteries but never directly above them — battery gases corrode the electronics — and keep about 10 cm free around it. Heat costs power: a 3000 VA unit gives 2400 W continuous at 25 °C but only 1700 W at 65 °C.18,5,2
  • Fuse the battery cable as the manual says: the MultiPlus 2 kVA has no internal DC fuse at all, while on the small 500–1600 VA units and the Compacts a reversed battery connection can blow the internal fuse. A MultiPlus-II with a suspected blown internal fuse goes to an authorised service centre.5,35,15,28,18

Videos & how-tos

Links to YouTube, nothing embedded. The maker’s own channel comes first; the rest are channels we found clear and correct for this model.

  • Inside the Victron MultiPlus and a detailed explanation of how it works Video Victron Energy · maker’s channel · EN · 19 min
  • MultiPlus-II introduction Video Victron Energy · maker’s channel · EN · 3 min
  • Updating MultiPlus firmware with an Android phone Video Victron Energy · maker’s channel · EN · 1 min
  • VEConfigure 3 basics: setting up a Multi on the computer Video Victron Energy · maker’s channel · EN · 6 min

On the marketplace

Browse the category on boatparts.app

Looking for a part for the Victron MultiPlus and MultiPlus-II? Post a wanted ad in the app — it is free, it sits on the live map, and boaters nearby who have the part aboard can answer.

Got spares you no longer need? List them in a minute. No commission, ever.

Get the app

Sources

  1. victronenergy.com/meters-and-sensors/temperature-sensor-qua-pmp-venus-gx
  2. victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-EN-.pdf
  3. victronenergy.com/upload/documents/Datasheet-MultiPlus-II-GX-inverter-charger-EN-.pdf
  4. victronenergy.com/media/pricelist/Pricelist_Web_Victron__EUR_C_2026-Q4_003.pdf
  5. victronenergy.com/upload/documents/MultiPlus_2kVA_230V/24547-MultiPlus_2kVA-pdf-en.pdf
  6. victronenergy.com/accessories/interface-mk3-usb
  7. victronenergy.com/media/pg/VictronConnect_configuration_guide_for_VE.Bus_products/en/limi…
  8. victronenergy.com/upload/documents/Datasheet-MultiPlus-inverter-charger-800VA-5kVA-EN-.pdf
  9. victronenergy.com/accessories/ve-bus-smart-dongle
  10. victronenergy.com/display-and-panels/digital-multi-control-panel-gx
  11. victronenergy.com/display-and-panels/digital-multi-control-200-200a
  12. victronenergy.com/upload/documents/Manual-MultiPlus-3k-230V-16A-50A-(firmware-xxxx4xx)-EN…
  13. victronenergy.com/cables/rj45-utp-cable
  14. victronenergy.com/cables/rj45-splitter
  15. victronenergy.com/upload/documents/Manual-MultiPlus-500VA-1200VA-EN-NL-FR-DE-ES-IT.pdf
  16. victronenergy.com/accessories/inverting-remote-on-off-cable
  17. victronenergy.com/battery-management-systems/ve-bus-bms
  18. victronenergy.com/upload/documents/MultiPlus-II_230V/32424-MultiPlus-II___Quattro-II-pdf-…
  19. victronenergy.com/battery-management-systems/ve-bus-bms-ng
  20. victronenergy.com/meters-and-sensors/current-transformer-for-multiplus-ii
  21. victronenergy.com/dc-distribution-systems/fuses-and-fuse-holders
  22. victronenergy.com/upload/documents/MultiPlus-II_4k_4k5_6k5_10k_230V/32424-MultiPlus-II___…
  23. victronenergy.com/upload/documents/Manual-MultiPlus-5k-100A-230V-(firmware-xxxx4xx)-EN-NL…
  24. victronenergy.com/upload/documents/Manual-MultiPlus-Compact-2000-230V-EN-NL-FR-DE-ES.pdf
  25. victronenergy.com/isolation-transformers/isolation-transformers-2000va-3600va-7000va
  26. victronenergy.com/upload/documents/MultiPlus-II_GX/2983-MultiPlus-II_GX-pdf-en.pdf
  27. victronenergy.com/upload/documents/Manual-MultiPlus-1600VA-EN-NL-FR-DE-ES-IT.pdf
  28. victronenergy.com/upload/documents/Manual-MultiPlus-Compact-800-1200-1600-EN-NL-FR-DE-ES.…
  29. victronenergy.com/media/pg/VictronConnect_configuration_guide_for_VE.Bus_products/en/firm…
  30. victronenergy.com/live/updating_firmware:updating_ve.bus_products
  31. victronenergy.com/upload/documents/180522-Victron-MultiPlus-II-launch-EN.pdf
  32. victronenergy.com/inverters-chargers/multi-500-va
  33. victronenergy.com/inverters-chargers/multiplus-12v-24v-48v-800va-3kva
  34. victronenergy.com/inverters-chargers/multiplus-2000-va
  35. victronenergy.com/upload/documents/Datasheet-MultiPlus-2kW-230V-new-models-EN.pdf
  36. victronenergy.com/inverters-chargers/multiplus-ii
  37. victronenergy.com/inverters-chargers/multiplus-ii-gx
  38. victronenergy.com/upload/documents/Datasheet-MultiPlus-II-inverter-charger-4k-4k5-6k5-10k…
  39. victronenergy.com/upload/documents/manual-VE.Bus-firmware-versions-explained-EN.pdf

Victron Energy is a trademark of its owner; boatparts.app is not affiliated with it. Part numbers are quoted for identification only. Spotted an error? Write to mail@boatparts.app.

boatparts.app

The marketplace that speaks boat.

@boatparts.app Facebook
  • Manuals
  • Contact
  • Press kit
  • Partners
  • Legal notice
  • Privacy Policy
  • Terms of Service
  • Report content
  • Delete account
© 2026 Thumanns LLC Map data © OpenStreetMap contributors · Tiles © CARTO