Frigoboat · Refrigeration
Frigoboat / Frigomatic refrigeration
Frigoboat is the marine refrigeration brand of Veco S.p.A. in Italy, which sells the same 12/24 V range in Europe as Frigomatic; in North America it comes through Coastal Climate Control. A kit turns an insulated icebox into a fridge or freezer: a condensing unit with a Secop (ex-Danfoss) BD35F or BD50F compressor, an aluminium or stainless evaporator and a thermostat, each pre-charged with R134a and joined by self-sealing quick couplings. The best-known version is the keel-cooled K35F/K50F, whose condenser is a sintered-bronze Keel Cooler through the hull, so it runs without fan or pump; the air-cooled Paris 35F and Capri 35F/50F and the pumped water-cooled W35F/W50F cover boats where no keel cooler is wanted. The ‘35’ units suit boxes up to about 7 cu ft (about 200 l) and the ‘50’ units larger fridges and freezers; the original Smart Speed Control has given way to the Merlin II, and older systems with Danfoss BD2, BD2.5 or BD3 compressors are not covered here.
- Manuals & documents
- Wear parts & part numbers
- Service intervals
- Specifications
- Good to know
- Fitted in
- On the marketplace
Manuals & documents
Frigoboat’s own website is gone (frigoboat.com is a parked domain) and Veco’s downloads need a dealer login, so the Frigoboat documents here come from Coastal Climate Control in Annapolis (USA), a distributor listed by Veco; the compressor data sheets and controller instructions come from Secop. We host no manuals.
- Frigoboat installation and instruction manual, Rev 42, all BD35/BD50 systems (Coastal Climate Control) Operation manual coastalclimatecontrol.com · PDF · EN
- Frigoboat BD35/BD50 troubleshooting guide, v20 (Coastal Climate Control) Servicing guide coastalclimatecontrol.com · PDF · EN
- Diagnostic LED: Danfoss/Secop compressor fault codes explained (Coastal Climate Control) Servicing guide coastalclimatecontrol.com · PDF · EN
- Power supply testing on Danfoss/Secop BD35/BD50 compressors (Coastal Climate Control) Servicing guide coastalclimatecontrol.com · PDF · EN
- R134a charge guidelines for Frigoboat systems (Coastal Climate Control) Servicing guide coastalclimatecontrol.com · PDF · EN
- Cap tube troubleshooting guide with diagram (Coastal Climate Control) Servicing guide coastalclimatecontrol.com · PDF · EN
- Replacing O-rings in Frigoboat couplings (Coastal Climate Control) Servicing guide coastalclimatecontrol.com · PDF · EN
- Merlin II mini smart speed controller, instructions v4 (Coastal Climate Control) Operation manual coastalclimatecontrol.com · PDF · EN
- W35/W50 pump and thermostat wiring (Coastal Climate Control) Wiring diagram coastalclimatecontrol.com · PDF · EN
- Adding a Keel Cooler to a Frigoboat air- or water-cooled system (Coastal Climate Control) Installation guide coastalclimatecontrol.com · PDF · EN
- Which Keel Cooler? Threads or studs, with or without zincs (Coastal Climate Control) Product leaflet coastalclimatecontrol.com · PDF · EN
- Keel Cooler systems data sheet, K35/K50 dimensions (Frigoboat, via Coastal Climate Control) Spec sheet coastalclimatecontrol.com · PDF · EN
- Secop BD35F compressor data sheet (101Z0200, R134a, 12/24 V, 2024) Spec sheet secop.com · PDF · EN
- Secop BD50F compressor data sheet (101Z1220, R134a, 12/24 V, 2024) Spec sheet secop.com · PDF · EN
- Secop electronic unit 101N0212 for BD35F/BD50F, instructions (end of life, 2019) Servicing guide secop.com · PDF · EN
- Secop electronic unit 101N0242 for BD35F/BD50F, instructions (2022) Servicing guide secop.com · PDF · EN
- Frigoboat manuals, wiring diagrams and drawings (Coastal Climate Control) Manual portal coastalclimatecontrol.com · EN
- Refrigeration troubleshooting documents (Coastal Climate Control) Manual portal coastalclimatecontrol.com · EN
- Veco Frigomatic 12/24 V refrigeration systems (downloads need a Veco login) Manual portal veco.net · EN
Wear parts & part numbers
| Part | OEM number | Also fits | Note |
|---|---|---|---|
| Control unit | 101N02121,2,3,4,5replaces 101N0200replaces 101N0210 | — | Secop (ex-Danfoss) electronic unit, 12/24 V, for every BD35F/BD50F unit: Paris 35F, Capri 35F/50F, W35F/W50F, K35F/K50F. Coastal sells it as E50896 and says it replaces 101N0200 and 101N0210. Secop’s 2024 data sheets list 101N0242 as the standard unit and file the 101N0212 as end-of-life; whether the 101N0242 swaps in directly with a Speed Board or Merlin II is unconfirmed, so ask the dealer first. |
| Control unit | 101N0510 · E525306,7,4,5,8 | — | AC/DC electronic unit, Secop 101N0510 = Frigoboat E52530: an optional replacement for the standard unit on any BD35F/BD50F that runs on 100–240 V shore power when it is there and on the 12/24 V battery otherwise. Coastal also names the older 101N0500. A Merlin II cannot plug onto it and is mounted remotely. |
| Speed controller | E510459 | — | Speed Board, the manual speed selector: plugs onto the standard 101N0212/101N0210 unit, set 2000–3500 rpm with a screwdriver, with a 12/24 V switch. Standard on Capri 35F/50F, W35F/W50F and K35F/K50F, not used on the Paris 35F; take it off when you fit a Merlin II. Number from one source (Coastal). |
| Speed controller | E5215210,3 | — | Merlin II mini smart speed controller, Coastal Climate Control’s own product: picks the speed automatically and replaces the Speed Board on the C, T and D terminals of the 101N0210/0212 unit; on the AC/DC unit it is mounted remotely. It succeeds the original Smart Speed Control (SSC) and the first Merlin, both obsolete. Number from one source (Coastal). |
| Thermostat | E25050011,12,13 | — | Mechanical fridge thermostat, white housing, for every Frigoboat/Frigomatic system with H, B or F evaporator: the capillary clamps to the evaporator plate, the two wires go to C and T. Some shops title it ‘freezer’; the white one is the fridge version. |
| Thermostat | E25070014,15,13 | — | Mechanical freezer thermostat, blue housing, for boxes run entirely as a freezer and for spillover systems; wired to C and T on the controller. |
| Thermostat | E5226016,17,18 | — | Digital fridge/freezer thermostat (Carel type), 12/24 V, with a 6 m probe: Frigoboat’s European version. North American systems usually have Coastal’s own MK3 instead (C3002-12 or C3002-24, one source). |
| Keel cooler | E50361 · E50361Z19,20,21,22 | — | Keel Cooler, the through-hull condenser of the K35F/K50F (also an add-on for Capri and W units), threaded mount: E50361 without zincs, E50361Z with two recessed zincs. The stud-mounted version is E50722 / E50722Z. Technofluid lists E50361 as the short-thread (45 mm) version. |
| Keel cooler | E50362 · E50362Z23,24,25 | — | Long-thread Keel Cooler for K35F/K50F: E50362 without, E50362Z with zincs. Veco confirms that a short- and a long-thread version exist; the numbers come from one source (Outback Marine, Australia). |
| Keel cooler anode | E5152527,28,20 | Martyr CM51525Z26 | Two per cooler, for the Z versions (E50361Z, E50722Z, E50362Z) on K35F/K50F and keel-plus-air systems. Outback Marine lists the current revision as E51525_r1. |
| Condenser | E5312529,30 | — | Air add-on condenser: an extra pre-charged air-cooled condenser for K35F/K50F (Coastal: also W35F/W50F), so the fridge can run while the boat is hauled out; mounted next to the compressor. |
| Relay | E25100213,31,32 | — | Pump relay with 12 V coil for W35F/W50F: the controller’s fan terminals switch the relay and the relay switches the pump, so the terminals are not overloaded. In the US it replaced the older pump interface E51385, which Technofluid (Italy) still lists for the Frigomatic W35/W50. |
| Raw water pump | A092819C33 | — | Self-priming 12 V cooling-water pump for W35F/W50F: about 1 A, 1.5 US gal/min, 5/8 in (16 mm) hose barbs; needs a strainer on the inlet. Number from one source (Coastal). |
| Mounting bracket | E5213513,34 | — | Bulkhead bracket for mounting a K35F, K50F, W35F or W50F on a vertical surface; it uses its own plastic mounts in place of the stainless ones. |
| O-ring | A5096035,36 | — | Main (outer) O-ring of the Frigoboat quick coupling, one per coupling on the male half; it can be changed without losing refrigerant. The small inner O-rings need the gas recovered first. Number from one source (Coastal). |
| Filter drier | E5327537,38 | — | Filter/drier with Frigoboat quick couplings, pre-charged: a repair part fitted after moisture in the system, a blocked cap tube or an evaporator replacement; a new installation needs none. Number from one source (Coastal). |
| Fan | E51335C · E250122C · E250102C39,40,41 | — | Condenser fans, 12 V: E51335C Capri 50F (120 mm; Coastal also lists it for the older AH35/AV35), E250122C Capri 35F (120 mm), E250102C Paris 35F and the older Roma 35 (90 mm). The C suffix may be Coastal’s own. Numbers from one source (Coastal). |
| Fan | E51591C42,13 | — | Micro fan on the controller heat sink of the K50F and W50F (the manual calls it the oil cooler fan), wired to F and + on the controller. Number from one source (Coastal). |
| Condensing unit (compressor) | E51975-0143,44,45replaces E51975 | — | Condensing unit K50F (keel-cooled, BD50F), compressor unit only; the keel cooler is sold separately. Coastal sells it as E51975SB (with Speed Board). |
| Condensing unit (compressor) | E50345X46 | — | Condensing unit K35F (keel-cooled, BD35F) with manual Speed Board; keel cooler sold separately. The X suffix may be the distributor’s own. Number from one source (Coastal). |
| Condensing unit (compressor) | E5197047,48 | — | Condensing unit W50F (pumped water-cooled, BD50F); needs a sea-water pump and a relay. Coastal sells it as E51970NA (North America, with Speed Board). |
| Condensing unit (compressor) | E50045X49 | — | Condensing unit W35F (pumped water-cooled, BD35F) with Speed Board; needs a sea-water pump and a relay. The suffix may be the distributor’s own. Number from one source (Coastal). |
| Condensing unit (compressor) | E51430 · E51420NA · E51135-0150,51,52 | — | Air-cooled condensing units: E51430 Capri 35F with Speed Board; E51420NA Capri 50F, North American version with 101N0212 and Speed Board; E51135-01 Paris 35F, fixed speed, only for 80F, 130F or 130H evaporators. Numbers from one source (Coastal). |
| Evaporator | E5088353 | — | Evaporator 80F, flat, 13 × 9.5 in, fridge up to 3 cu ft. Every evaporator comes with about 9 ft (2.8 m) of pre-charged tubing and Frigoboat quick couplings and works with BD35F and BD50F units; choose by box size. Number from one source (Coastal). |
| Evaporator | E50085 · E5006554,55,56 | — | Evaporators 130: E50085 = 130F, flat and bendable, 23.25 × 8.25 in, fridge up to 5 cu ft or freezer up to 2.5 cu ft; E50065 = 130H, horizontal with freezer compartment, 10 × 2.5 × 8.5 in, fridge up to 5 cu ft (130H number from one source, Coastal). |
| Evaporator | E50095 · E5009057,58,59,60 | — | Evaporators 160: E50095 = 160F, flat and bendable, 31.7 × 8.3 in, fridge 5–10 cu ft or freezer 2–5 cu ft; E50090 = 160H, horizontal, 12.5 × 4.5 × 8.5 in, fridge 5–10 cu ft. |
| Evaporator | E5210561 | — | Evaporator 180F-SS, flat with stainless cover, 22 × 12 in, fridge 5–10 cu ft; not for freezers. Number from one source (Coastal). |
| Evaporator | E50075 · E5007062,63,64,65 | — | Evaporators 200: E50075 = 200F, flat and bendable, 42 × 10.5 in, fridge 10–18 cu ft or freezer 5–8 cu ft; E50070 = 200H, horizontal with freezer compartment. |
| Evaporator | E53335 · E53335H66,67 | — | Evaporators 250: E53335 = 250B, vertical bin, 10 × 10.2 × 6.5 in, fridge 5–10 cu ft; E53335H = 250H, the same bin mounted horizontally with a lid kit. Numbers from one source (Coastal). |
| Evaporator | E50105 · E50105H68,69 | — | Evaporators 340: E50105 = 340B, vertical bin, 15 × 11.5 × 6 in, fridge 10–15 cu ft; E50105H = 340H, the same bin mounted horizontally with a lid. Numbers from one source (Coastal). |
| Evaporator | E52225 · E5218570,71,72 | — | Evaporators 380: E52225 = 380F-AL, flat aluminium, 39.2 × 14.5 in, fridge 10–20 cu ft or freezer 5–10 cu ft; E52185 = 380F-SS, flat with stainless cover, 40.2 × 16.2 in, fridge 10–15 cu ft, not for freezers (380F-SS number from one source, Coastal). |
Numbers checked against the sources below on 13 October 2026. Always confirm against your serial number and exact type before ordering.
Service intervals
| Task | Interval |
|---|---|
| Anode | Whenever the boat is out of the water: check the keel cooler for corrosion and, on the Z versions, its two zincs (E51525); they go quickly if the cooler is also tied into the boat’s bonding and anode system20,13 |
| Keel cooler cleaning | Periodically (Frigoboat gives no fixed interval): brush it clean, never with a metal scraper, and paint the sintered plate only if fouling is heavy and keeps coming back13 |
| Quick couplings | No routine replacement. If one hisses, separate the halves and re-seat or replace the main O-ring (A50960); spares come taped to the compressor. Tighten snug only, hold the male half still, no tape or sealant13,36 |
From the Frigoboat installation and instruction manual (Rev 42) and Coastal Climate Control’s keel cooler and O-ring guides. Frigoboat sets no hour or month intervals; the compressor oil is a factory fill that is never topped up.
Specifications
| Versions | Air-cooled: Paris 35F (fixed speed), Capri 35F, Capri 50F · pumped sea water: W35F, W50F · keel-cooled: K35F, K50F with the Keel Cooler · keel plus air: a Capri with an added Keel Cooler, or a K or W unit with the air add-on condenser. Sold in Europe as Frigomatic13,25 |
|---|---|
| Compressor | Secop (ex-Danfoss) BD35F in Paris 35F, Capri 35F, W35F and K35F; BD50F in Capri 50F, W50F and K50F. Variable speed 2000–3500 rpm, displacement 2.0 cm³ (BD35F) / 2.5 cm³ (BD50F). Current Secop codes: BD35F 101Z0200, BD50F 101Z122013,4,5 |
| Refrigerant | R134a; every component is factory pre-charged and joined by self-sealing couplings. Pure R134a only: no leak sealer, dye, extra oil or other additives. Frigoboat publishes no charge in grams, so judge it by the frost pattern: after a long run, a thin, even frost over the whole plate and no frost or sweating on the return line13,73 |
| Voltage | 12 or 24 V DC, detected automatically (24 V mode above 17 V); low-voltage cut-out below 10.4 V (22.8 V) at the controller terminals, restart above 11.7 V (24.2 V). The AC/DC electronic unit 101N0510 also runs on 100–240 V AC, 50/60 Hz13,4 |
| Current draw | 12 V, Secop data at −10 °C evaporating and 32 °C ambient: BD35F about 3.1 A at 2000 rpm up to 5.5 A at 3500 rpm, BD50F about 4.3–7.6 A. Freezer duty (−25 °C): BD35F 1.9–3.4 A, BD50F 2.6–4.7 A. About half these figures at 24 V4,5 |
| Cooling capacity | (EN 12900, −10 °C evaporating, 12 V): BD35F 56.5 W (about 190 BTU/h) at 2000 rpm to 93.9 W (about 320 BTU/h) at 3500 rpm; BD50F 72.8 W (about 250 BTU/h) to 123 W (about 420 BTU/h)4,5 |
| Speed settings | Speed Board settings, fridge / freezer in rpm: 80F 2000 / –; 130H, 130F 2500 / 3000; 160H, 160F, 180F-SS 2500 / 3500; 200H, 200B, 200F, 250B 3000 / 3500; 340B, 380F-SS 3500 / 3500. Without speed control the compressor runs at its slowest speed (2000 rpm); the Paris 35F has none13 |
| Box size | With good insulation, fridge / freezer: Paris 35F under 5 / under 2.5 cu ft; Capri 35F, K35F up to 7 / 4; W35F up to 7 / 5; Capri 50F 7–18 / 4–9; K50F, W50F 7–20 / 5–10 cu ft (1 cu ft ≈ 28 l)52,50,51,46,45,49,48 |
| Breaker / fuse | 15 A fast-blow fuse or breaker at 12 V, 7.5 A at 24 V; main switch rated at least 20 A13 |
| Power cable size | Never thinner than 10 AWG (Secop: 6 mm² for up to 6 m one way at 12 V); thicker cable must step down to 10 AWG at the controller terminals13,2 |
| Cooling | W35F/W50F: sea water only, self-priming 12 V pump (about 1 A, 1.5 US gal/min, lifts 2 m) with a 120-mesh strainer, at least 1 US gal/min. The controller’s fan output gives 12 V even on 24 V and carries max. 0.7 A (Secop: 0.5 A average), so the pump runs through a 12 V relay; one pump can serve up to three units in parallel. A thermal cut-out on the condenser stops the system above 55 °C (130 °F)13,32,25,33,2 |
| Mounting | Keel Cooler: sintered bronze over a cupro-nickel loop; through-hull hole 1 9/16 in (40 mm), shaft 1.5 in / 38 mm. Below the waterline and within 5 ft (1.5 m) of the compressor, never extended; max. 30° heel for continuous duty. Bond it to battery negative with green 8 AWG wire, no switch in the line. The filter/drier on the discharge tube stands vertical, arrow down13,21,25 |
| Evaporators | F, flat and bendable: 80F, 130F, 160F, 200F, 380F; F-SS with stainless cover: 180F-SS, 380F-SS; H, horizontal with freezer compartment: 130H, 160H, 200H, 250H, 340H; B, vertical bin: 250B, 340B. Pre-charged tubing about 9 ft / 2.8 m; extensions 3, 6 and 10 ft (US) or 1–6 m (Veco). Minimum bend radius 1.5 in per the manual (Veco: 25 mm)13,25 |
| Fault codes | Read them with a 12 V LED across + and D (or on a Merlin II or Coastal MK3 display); the LED flashes the code every few seconds: 1 supply voltage too low (by far the most common) · 2 fan or pump overload · 3 compressor could not start (normal after a quick off and on) · 4 speed below minimum · 5 electronics too hot (often a dirty condenser, a fouled keel cooler or overcharge) · 6 NTC thermostat fault (newer Secop units only)74 |
| Lubrication | Compressor: 150 cm³ polyolester oil, factory fill; never add oil4,13 |
| Weight | Bare BD35F or BD50F compressor 4.3 kg plus 0.19 kg for the electronic unit; the complete condensing units are not published4,5 |
Good to know
- Read the fault LED before you buy parts: code 1, supply voltage too low, is by far the most common, and most ‘dead compressor’ cases turn out to be wiring. Measure the voltage at the controller’s own + and − terminals while the compressor tries to start; if it sags well below the battery voltage, look for a tired fuse holder, breaker or negative bus connection before you change the controller.74,75
- Speed control decides your power use. With only a thermostat on C and T the compressor runs at its slowest speed; the Speed Board lets you set 2000–3500 rpm by hand, while the Merlin II picks the speed itself and ramps up gently from a warm start. Never fit both: take the Speed Board off when you install a Merlin II.13,3
- Keel cooling is the quietest and most efficient option, with no fan and no pump, and suits warm water. Air cooling is cheapest but needs cool intake air, never air from the engine room. A keel-cooled unit must not run with the boat hauled out unless you add the air add-on condenser or rig temporary water cooling; on keel-plus-air setups, run the fan only ashore.13
- Bond the keel cooler to battery negative with no switch in the line. Choose the zinc (Z) version only if the cooler is not already tied into the boat’s bonding and anode system; otherwise its two zincs get eaten quickly.20
- Box temperature problems are often the box itself: plug the drain, seal the tube hole and test the lid seal by closing it on a banknote, which should be gripped. Defrost by switching off at the breaker and letting the ice thaw; never chip ice off the aluminium plate or use a heat gun or hair dryer.13
- Listings found through ‘BD35F’ or ‘BD50F’ may come from other fridges built on the same Secop compressor, such as Isotherm or Waeco units. The compressor and its Secop electronic unit (101N0212, 101N0510) are the same parts there, so such listings can fit your Frigoboat; for evaporators, couplings and thermostats, go by the Frigoboat numbers above.4,5,2
Fitted in
Boats whose builder lists it as standard or optional equipment:
- Nautitech 40 Open — Frigoboat (First boats: two fridge drawers by Frigoboat in the galley (SAIL 2015; ‘two-drawer fridge’ in Cruising World 2015), a small cockpit fridge as an option)
On the marketplace
Looking for a part for Frigoboat / Frigomatic refrigeration? Post a wanted ad in the app — it is free, it sits on the live map, and boaters nearby who have the part aboard can answer.
Got spares you no longer need? List them in a minute. No commission, ever.
Sources
- store12438129.company.site/Control-module-12v-24v-for-BD35-50-Compressors-p468428529
- secop.com/fileadmin/user_upload/technical-literature/electronic-units-instructions/eol/bd…
- coastalclimatecontrol.com/component/edocman/467-merlin-ii-mini-smart-speed-controller-v4/…
- secop.com/fileadmin/user_upload/SEPS/datasheets/en/bd35f_101z0200_r134a_12-24vdc_09-2024_…
- secop.com/fileadmin/user_upload/SEPS/datasheets/en/bd50f_101z1220_r134a_12-24vdc_09-2024_…
- store12438129.company.site/Control-module-AC-DC-for-BD35-50-Compressors-p95699115
- outbackmarine.com.au/danfoss-controller-for-bd35-50f-with-ac-main-adapt
- coastalclimatecontrol.com/refrigeration/installation
- store12438129.company.site/Speed-Board-manual-p95699151
- store12438129.company.site/Merlin-II-mini-smart-speed-board-p95699145
- store12438129.company.site/Thermostat-Refrigerator-Mechanical-p95699157
- technofluid.it/en/product/frigomatic-refrigerator-thermostat-code-e250500-veco/
- coastalclimatecontrol.com/component/edocman/272-frigoboat-installation-and-instruction-ma…
- store12438129.company.site/Thermostat-Freezer-Mechanical-p95699156
- technofluid.it/en/product/frigomatic-freezer-thermostat-code-e250700-veco/
- outbackmarine.com.au/digital-thermostat-carel-for-fridge-and-freezers
- technofluid.it/en/product/digital-fridge-freezer-thermostat-1224vac-with-6m-probe-code-e5…
- store12438129.company.site/Coastal-MK3-Digital-Thermostat-12v-or-24v-pre-wired-p129867059
- store12438129.company.site/Keel-Cooler-thread-mounted-condenser-p95699139
- coastalclimatecontrol.com/images/PDF/which_keel_cooler_should_i_use.pdf
- coastalclimatecontrol.com/images/PDF/Refer/Keel-Cooler-Dimensions.pdf
- technofluid.it/en/product/frigomatic-outboard-with-thread-without-zincs-code-e50361-frigo…
- outbackmarine.com.au/ground-plate-keel-cooler-thread-115mm-without-zinc
- outbackmarine.com.au/frigoboat-keel-cooler-with-zinc-anode-studs
- veco.net/en/prodotti/frigomatic/
- fisheriessupply.com/martyr-frigo-boat-anode/cm51525z
- store12438129.company.site/Zincs-Set-of-2-for-Keel-Cooler-p95699168
- outbackmarine.com.au/anode-for-keel-cooled-condensor
- store12438129.company.site/Air-Add-on-Frigoboat-Condenser-p95699107
- outbackmarine.com.au/additional-air-condenser-for-frigomatic-k35-50
- store12438129.company.site/Pump-relay-12v-p95699277
- coastalclimatecontrol.com/component/edocman/469-w35-w50-pump-and-thermostat-wiring-direct…
- store12438129.company.site/Frigoboat-12v-Self-Priming-Pump-p787446888
- store12438129.company.site/Bracket-bulkhead-mounting-of-K35-K50-W35-or-W50-Compressors-p9…
- store12438129.company.site/O-ring-for-Frigoboat-quick-disconnect-connect-fitting-p95699264
- coastalclimatecontrol.com/component/edocman/230-replacing-o-rings-in-frigoboat-couplings/…
- store12438129.company.site/Filter-Drier-p95699130
- coastalclimatecontrol.com/component/edocman/188-cap-tube-troubleshooting-guide-with-diagr…
- store12438129.company.site/Fan-Lg-for-Frigoboat-Capri-50-12v-DC-p95699126
- store12438129.company.site/Fan-Lg-for-Frigoboat-Capri35-p95699127
- store12438129.company.site/Fan-Med-for-Frigoboat-Paris35-Roma35-p95699128
- store12438129.company.site/Fan-Micro-for-BD50-compressor-heat-sync-p95699257
- outbackmarine.com.au/frigomatic-k-50f-12-24v-80gr-dissipator
- technofluid.it/en/product/frigoboat-frigomatic-k-50f-1224v-code-e51975-veco/
- store12438129.company.site/Keel-cooled-K50F-p95699136
- store12438129.company.site/Keel-cooled-K35F-with-manual-speed-board-p95699135
- technofluid.it/en/product/frigomatic-w-50f-12-24v-code-e51970-veco/
- store12438129.company.site/Pumped-water-cooled-W50F-with-manual-speed-board-p485001791
- store12438129.company.site/Pumped-water-cooled-W35F-with-manual-speed-board-p95699166
- store12438129.company.site/Air-cooled-Capri-35F-with-manual-speed-board-p485004534
- store12438129.company.site/Air-cooled-Capri-50F-speed-board-required-p485004532
- store12438129.company.site/Air-cooled-Paris-35F-with-standard-control-module-p95699146
- store12438129.company.site/80F-Evaporator-13-w-x-9-5-h-Flat-Plate-p95699098
- store12438129.company.site/130F-Evaporator-23-25-w-x-8-25-h-Bendable-Flat-Plate-p95699067
- outbackmarine.com.au/flat-evaporator-130f-r134a
- store12438129.company.site/130H-Evaporator-10-w-x-2-5-h-x-8-5-Horizontal-Plate-p95699068
- store12438129.company.site/160F-Evaporator-31-7-w-x-8-3-h-Bendable-Flat-Plate-p95699072
- outbackmarine.com.au/flat-evaporator-160f-r134a
- store12438129.company.site/160H-Evaporator-12-5-w-x-4-5-h-x-8-5-d-p95699073
- outbackmarine.com.au/evaporator-200h-r134a~68764
- store12438129.company.site/180F-SS-Evaporator-22-w-x-12-h-with-stainless-steel-cover-p956…
- store12438129.company.site/200F-Evaporator-42-w-x-10-5-h-Bendable-Flat-Plate-p95699075
- outbackmarine.com.au/flat-evaporator-200f-r134a
- outbackmarine.com.au/evaporator-200h-r134a
- technofluid.it/en/product/200h-horizontal-evaporator-s-t-r134a-code-e50070-veco/
- store12438129.company.site/250B-Evaporator-10-w-x-10-2-h-x-6-5-d-Vertical-bin-p95699077
- store12438129.company.site/250H-Evaporator-10-w-x-6-5-h-x-10-2-d-w-Lid-kit-p95699078
- store12438129.company.site/340B-Evaporator-15-w-x-11-5-h-x-6-d-p95699082
- store12438129.company.site/340H-Evaporator-15-w-x-6-h-x-11-5-d-p95699083
- store12438129.company.site/380F-AL-Evaporator-39-2w-x-14-5-h-Flat-Plate-p95699084
- outbackmarine.com.au/flat-evaporator-380f-r134a
- store12438129.company.site/380F-SS-Evaporator-40-2-w-x-16-2-h-Flat-Plate-with-stainless-s…
- coastalclimatecontrol.com/component/edocman/207-r134a-charge-guidelines-for-frigoboat-sys…
- coastalclimatecontrol.com/component/edocman/271-diagnostic-led-danfoss-secop-compressor-f…
- coastalclimatecontrol.com/component/edocman/227-power-supply-testing-on-danfoss-secop-bd3…
Frigoboat is a trademark of its owner; boatparts.app is not affiliated with it. Part numbers are quoted for identification only. Spotted an error? Write to mail@boatparts.app.