Skip to content
boatparts.app
  • Browse parts
  • Map
  • Manuals
  • Contact
EN
English Deutsch Français Español
Get the app
Home Browse parts Map Manuals Contact Privacy Terms Legal notice Get the app
Service › Engine & equipment manuals › Quick Prince DP2 / DP3

Quick · Windlass

Quick Prince DP2 / DP3

The Prince DP is Quick’s vertical windlass range for boats of about 5 to 15 m: a low deck unit with the gypsy (and an optional drum) on top, the motor-gearbox below deck, a cone clutch that the lever releases, and a contactor box in the package. The DP2 (300–1000 W, 6–8 mm or 1/4–5/16 in chain) and the DP3 (700–1500 W, 8–10 mm or 5/16–3/8 in chain) are the core sizes; the DP1 is the small 300/500 W sibling for 6 mm or 1/4 in chain only. A P in the code (DP1 P, DP2 P, DP3 P) stands for the technopolymer gearbox housing, while the DP2E (500/800 W, epicyclic aluminium gearbox) and the 350 W DP2L 770 are separate DP2 versions with their own manuals; all of them are still in Quick’s 2026 catalogue. Quick, based in Ravenna, Italy, sells spares as numbered ‘OSP’ kits (gypsy, clutch cones, shaft kit with seals and bearing, motor, gearbox) and lists them with exploded views in each manual.

  • Manuals & documents
  • Wear parts & part numbers
  • Service intervals
  • Specifications
  • Good to know
  • On the marketplace

Manuals & documents

The links go straight to Quick. We host no manuals or drawings — the manufacturer’s copy is the current one.

  • Prince DP series (DP1 P, DP2 P, DP3 P, DP3 1500): installation and user’s manual with spare-part codes, rev. 001C (2022) Operation manual quickitaly.com · PDF · EN · DE · FR · ES · IT · PT
  • Prince DP2E 600/1000/1100: manual with spare-part codes in five languages, rev. 000A Operation manual quickitaly.com · PDF · IT · EN · FR · DE · ES
  • Prince DP2L 770: installation and user’s manual, rev. 000A Operation manual quickitaly.com · PDF · EN · DE · FR · ES · IT · PT
  • Contactor units T6315 and T6415: installation manual Installation guide quickitaly.com · PDF · IT · EN · FR · DE · ES
  • WCB hydraulic-magnetic circuit breaker: installation and use Installation guide quickitaly.com · PDF · IT · EN · FR · DE · ES
  • Foot switch Mod. 900: installation manual Installation guide quickitaly.com · PDF · IT · EN · FR · DE · ES
  • HRC handheld remote control: installation manual, rev. 005D Installation guide quickitaly.com · PDF · IT · EN · FR · DE · ES
  • Quick catalogue, September 2026: Prince DP data, contactor box and breaker per model (83.6 MB) Brochure quickitaly.com · PDF · IT · EN
  • Quick manuals and drilling templates for all current windlasses Manual portal quickitaly.com · EN

Wear parts & part numbers

PartOEM numberAlso fitsNote
Chain gypsyFVSSBDP20600A00 · FVSSBDP20140A00 · FVSSBDP20800A00 · FVSSBDP20516A001,2,3—DP2 gypsies, in order: 6 mm, 7 mm–1/4 in, 8 mm, 5/16 in. They fit the DP2 P 300–1000 W and the DP2E (same codes in its manual); rope and chain run on the same gypsy with Quick’s splice.
Chain gypsyFVSSBDP38516A00 · FVSSBDP31038A001,3—DP3 gypsies: 8 mm–5/16 in and 10 mm–3/8 in. They fit the DP3 P 700/1000 W and the DP3 1500.
Chain gypsyFVSSB0406000A00 · FVSSB0401400A001,4,3—DP1 gypsies: 6 mm DIN 766/ISO and 1/4 in BBB, for the DP1 P 300/500 W. Quick lists the same gypsies for the Eagle E1 and the Rider R1 P.
Clutch coneFVSSCFASC000A001,2—Top and bottom cone for the DP2 P 300–1000 W. The DP2E manual lists its cones singly: MSF07G000000 (top) and MSF08ASCN000 (bottom).
Clutch coneFVSSCFANHC00A001,5,6—Cone kit for every DP3. Quick lists the same kit for the Aleph AL3, Hector HC3 and Antares AT.
Clutch coneFVSSCFDP1000A001—Cone kit for the DP1 P 300/500 W.
Driveshaft kitFVSSADP2000SA00 · FVSSADP200DSA00 · FVSSADP2000LA00 · FVSSADP200DLA001—DP2 main shaft with both oil seals, bearing, snap rings and keys; this is how you renew the shaft seals. In order: 300/500 W, 300/500 W with drum, 700/1000 W, 700/1000 W with drum.
Driveshaft kitFVSSADP30000A00 · FVSSADP300D0A001—DP3 shaft kit without / with drum, with both oil seals, bearing and snap rings.
Driveshaft kitFVSSADP10000A00 · FVSSADP100D0A001—DP1 shaft kit without / with drum, with oil seals, bearing and snap rings.
Roller bearingFVSSCUDP1000000 · FVSSCUDP2E00A00 · FVSSCUDP30000007—Bearing and circlip kits for DP1 / DP2E / DP3. One source: Jimmy Green Marine lists them for the Prince DP; they are not in Quick’s manuals and two codes lack the usual A00 ending, so confirm with the dealer. The shaft kits above also contain the bearing.
Clutch leverFVSSLVSDN000A001,2,8—Straight nylon lever for the DP1, the DP2 300/500 W and the DP2E: turn it anticlockwise in the gypsy cover or drum bush to release the clutch, clockwise to engage it. The DP1 parts list prints the code with an extra 0.
Clutch leverFVSSLVSP00R2A001—Curved lever R2 for the DP2 700/1000 W and every DP3.
MotorFVSSM0312000A00 · FVSSM0512000A001—Bare motor (without gearbox) for DP1 P and DP2 P: 300 W 12 V, 500 W 12 V. For the 500 W 24 V motor the DP manual prints the same code as for 12 V, so confirm the 24 V code with a Quick dealer.
MotorFVSSM0712000A00 · FVSSM0724000A00 · FVSSM1012000A00 · FVSSM1024000A001,4,5—Bare motor for DP2 P 700/1000 W and DP3 P: 700 W 12 V, 700 W 24 V, 1000 W 12 V, 1000 W 24 V. The same motors serve the Rider R3 and the Aleph AL3.
MotorFVSSM1512000A00 · FVSSM1524000A001,5—Bare motor for the DP3 1500, 12 V / 24 V; also listed for the Aleph AL3 1500.
Control box / solenoidT6415-12 · T6415-249,10,1—Reversing contactor unit, 12 V / 24 V, supplied with the DP1 P, the DP2 P 300/500 W and the DP2E; IP66, for motors up to 2500 W (12 V) or 3500 W (24 V). Mount it where no water can reach it.
Control box / solenoidT6315-12 · T6315-249,10,1—Contactor unit, 12 V / 24 V, supplied with the DP2 P 700/1000 W and every DP3.
Control box / solenoidT6411-129,11—Reversing contactor unit supplied with the DP2L 770 (12 V).
Circuit breakerWCB 40 · WCB 50 · WCB 60 · WCB 80 · WCB 10012,9,1—Quick’s hydraulic-magnetic DC breaker, 40 / 50 / 60 / 80 / 100 A, reset by hand; the rating for each model is under Breaker in the specifications. Switch it off to isolate the windlass under way.
Foot switch900/UW · 900/DW · 900/UB · 900/DB13,14,1—Up white / down white / up black / down black; the 900X has a stainless trim and the Mod. 915 is a combined up/down switch. Recommended in the DP manual; contacts rated 5 A.
Remote controlHRC 10021,15,9—Wired two-button UP/DOWN handheld remote, recommended in the DP manual.
Up/down switchWCS 820 · WCS 830 · WCS B1—Up/down switches for the helm panel, recommended in the DP manual.
Gearbox (without motor)FVSSMR05TG40B00 · FVSSMR0540HSB00 · FVSSMR10TG50B00 · FVSSMR15TG70A001—Gearbox without motor: TG40 500 W for DP1 P and DP2 P 300/500 W; TG40 HS for the Hi-Speed 500 W; TG50 1000 W for DP2 P 700/1000 W and DP3 P; TG70 1500 W for the DP3 1500.
Motor-gearbox unitFVSSR0312Q00B00 · FVSSR0512Q00B00 · FVSSR0524Q00B00 · FVSSR0512QHSB00 · FVSSR0524QHSB00 · FVSSR0712Q00B00 · FVSSR0724Q00B00 · FVSSR1012Q00B00 · FVSSR1024Q00B001—Complete motor-gearbox for DP1 P, DP2 P and DP3 P, in order: 300 W 12 V; 500 W 12 V; 500 W 24 V; Hi-Speed 500 W 12 V; Hi-Speed 500 W 24 V; 700 W 12 V; 700 W 24 V; 1000 W 12 V; 1000 W 24 V.
Motor-gearbox unitFVSSR1512Q00A00 · FVSSR1524Q00A001—Complete motor-gearbox for the DP3 1500, 12 V / 24 V.
Motor-gearbox unitFVSSR0612E00A00 · FVSSR0812E00A00 · FVSSR0824E00A00 · FVSSR0612ED0A00 · FVSSR0812ED0A00 · FVSSR0824ED0A002—DP2E motor-gearbox: DP2E 600 (12 V), DP2E 1000 (12 V), DP2E 1100 (24 V); the ED codes are for the versions with drum.
Pressure lever kit (rope tensioner)FVSSTCDP3000A001,16—Pressure lever with spring and pin for the DP3; it keeps the rope pressed into the gypsy.
Pressure lever kit (rope tensioner)FVSSTCDP2000A0016—Pressure lever kit for the DP2. One source: Jimmy Green Marine lists it for the DP2; Quick’s DP manual shows the DP2 pressure lever only as single parts.

Numbers checked against the sources below on 13 October 2026. Always confirm against your serial number and exact type before ordering.

Service intervals

TaskInterval
Fresh-water washRegularly: rinse every surface where salt can settle with fresh water1
Strip, clean & greaseOnce a year: take off the drum or gypsy cover, top cone, stripper, gypsy and bottom cone; clean them and grease the shaft thread and the cone seats with marine grease1,2
Electrical connectionsOnce a year, with the gypsy service: remove oxide from the motor and contactor terminals, then grease them1

From section 7 (Maintenance) of Quick’s DP series manual rev. 001C; the DP2E and DP2L 770 manuals also call for stripping the gypsy once a year. Quick gives no operating hours, only ‘periodically’ and ‘once a year’. Switch the power to the motor off before working on the windlass.

Specifications

TypeVertical windlass: deck unit with gypsy, motor-gearbox below deck, cone clutch released with the lever (the anchor drops with the clutch open); with drum (D) or gypsy cover only. DP2 and DP3 take rope and chain on one gypsy, the DP1 chain only1,9
ModelsDP1 P 300 W (boats 5–7.5 m) and 500 W (5–8.5 m); DP2 P 300 W (5–7.5 m), 500 W (5–9 m), 700 W (7–12 m), 1000 W (8–13 m); DP3 P 700 W (7–12 m), 1000 W (10–14 m); DP3 1500 W (12–15 m); DP2E 600 (500 W, 6–10 m), DP2E 1000 and 1100 (800 W, 7–12 m); DP2L 770 (350 W, 6–8 m). Hi-Speed 500 W versions of DP1 and DP2 on request. Quick’s boat lengths depend on boat type and rode9,1,2,11
VersionsModel code = series + gearbox + power + voltage + drum, e.g. DP2 P 7 12 D: Prince DP2, technopolymer gearbox (P; no letter = aluminium), 700 W, 12 V, with drum (D; without D = gypsy cover only). The DP2L 770 carries its maximum pull in lb instead (770 lb = 350 kg)1,11
Voltage12 V or 24 V DC; the 300 W models, DP2E 600/1000 and DP2L 770 12 V only, DP2E 1100 24 V9,1
Max pull / working loadMaximum instantaneous pull: DP1 P and DP2 P 300 W 370 kg, 500 W 660 kg (Hi-Speed 600 kg); DP2 P 700 W 680 kg, 1000 W 930 kg; DP3 P 700 W 850 kg, 1000 W 1000 kg; DP3 1500 W 1100 kg; DP2E 500 W 620 kg, 800 W 820 kg; DP2L 770 350 kg. The working load is far lower, e.g. 140 kg for a DP2 P 1000 W at 12 V1,9,2,11
Chain sizeDP1: 6 mm DIN 766/ISO or 1/4 in BBB. DP2 and DP2E: 6 mm DIN 766/ISO; one 7 mm–1/4 in gypsy for 7 mm DIN 766/ISO and 1/4 in G4/BBB; 8 mm DIN 766/ISO; 5/16 in G4. DP3: 8 mm DIN 766/ISO and 5/16 in G4/BBB on one gypsy, 10 mm ISO and 3/8 in G4 on the other. DP2L 770: 6 mm or 7 mm–1/4 in1,9
Rope sizeDP2, DP2E and DP2L 770: 1/2 in (12.7 mm) three-strand polyester; DP3: 1/2–5/8 in (12.7–15.8 mm) on the 8 mm–5/16 in gypsy, 5/8 in on the 10 mm gypsy. Only with Quick’s own rope-to-chain splice; the DP1 takes chain only1,9
Breaker / fuseQuick WCB hydraulic-magnetic breaker, 12 V / 24 V: DP1 P and DP2 P 300 W 50 A; DP1 P and DP2 P 500 W 60 / 40 A, Hi-Speed 500 W 80 / 40 A; DP2 P 700 W 50 / 40 A, 1000 W 80 / 50 A; DP3 P 700 W 50 / 40 A, 1000 W 80 / 50 A; DP3 1500 W 100 / 50 A; DP2E 500 W 50 A, 800 W 80 / 40 A; DP2L 770 40 A9,1
Power cable sizeMinimum motor cable for a total run of up to 20 m, 12 V / 24 V: 700 W 25 / 10 mm²; 1000 W 35 / 16 mm²; 1500 W 50 / 25 mm². Longer runs need a bigger section1,5
MountingDeck thickness: DP1 P 20–30 mm; DP2 P and DP3 P 25–50 mm; DP3 1500 30–50 mm; DP2E and DP2L 770 20–40 mm. Longer shafts and studs on request1,9
GearboxQuick TG40 on the 300/500 W models (also a Hi-Speed version), TG50 on 700/1000 W, TG70 on the DP3 1500; on the P versions the gearbox housing is technopolymer. The DP2E has an epicyclic gearbox in anodised aluminium, the DP2L 770 a cascade gearmotor in a BMC housing1,9
LubricationMarine grease on the main-shaft thread and on the gypsy faces where the clutch cones sit; clean the motor and contactor terminals and grease them1
Years builtCurrent range in Quick’s September 2026 catalogue (DP1 P, DP2 P, DP2E, DP2L 770, DP3); DP series manual at rev. 001C (December 2022); no launch year in Quick’s documents9,1

Good to know

  • Once a year strip the top: undo the gypsy cover or drum bush with the lever, lift off the top cone, undo the stripper screws, then take out the gypsy and the bottom cone. Clean everything and put marine grease on the shaft thread and the cone seats before reassembly.1
  • Switch the windlass breaker off before you put the lever in: someone at the remote or a foot switch could otherwise start the motor with the lever still in the drum or gypsy cover.1
  • Do not lie at anchor on the windlass: once anchored, put the chain on a stopper or bollard, secure it again before sailing off, and isolate the windlass with its breaker under way.1
  • If it stalls under load, wait a few seconds and try again in short bursts instead of holding the button. If the breaker tripped, reset it and give the motor a few minutes; if the anchor still will not come up, motor the boat over it.1
  • Several Prince spares are shared: the DP3 cone kit FVSSCFANHC00A00 is the one for the Aleph AL3, Hector HC3 and Antares too, and the DP1 gypsies also fit the Eagle E1 and Rider R1 P. Order by the code, not the model name.1,5,4
  • Order a gypsy by chain standard, not just by size: 6 mm DIN 766 and 1/4 in BBB (DP1), or 8 mm and 5/16 in G4 (DP2), need different gypsies. Rope-and-chain gypsies only work properly with Quick’s own rope-to-chain splice.1

On the marketplace

Browse the category on boatparts.app

Looking for a part for Quick Prince DP2 and DP3 windlasses? Post a wanted ad in the app — it is free, it sits on the live map, and boaters nearby who have the part aboard can answer.

Got spares you no longer need? List them in a minute. No commission, ever.

Get the app

Sources

  1. quickitaly.com/resources/downloads_qne-prod/1/DPSeries_rev001C_EN.pdf
  2. quickitaly.com/resources/downloads_qne-prod/DP2E_6_10_11%20Rev%2000A.pdf
  3. jimmygreen.com/product/quick-windlass-osp-replacement-gypsy/
  4. quickitaly.com/resources/downloads_qne-prod/2/R_series/RSeries_rev01A_EN_02_2026.pdf
  5. quickitaly.com/resources/downloads_qne-prod/1/AL3Series_rev000A_EN.pdf
  6. quickitaly.com/resources/downloads_qne-prod/1/HC3%207-10-15%20Rev%2008A.pdf
  7. jimmygreen.com/product/quick-osp-dp-vertical-windlass-bearings-kits/
  8. jimmygreen.com/product/quick-windlass-handle/
  9. quickitaly.com/resources/downloads_qne-oth/QNE_Catalogue_Ed26_September2026.pdf
  10. quickitaly.com/resources/downloads_qne-prod/1/T6315-xx_T6415-xx_Rev002A.pdf
  11. quickitaly.com/resources/downloads_qne-prod/1/DP2L_rev000A_EN.pdf
  12. quickitaly.com/resources/downloads_qne-prod/1/Fist_01A_WCB_magnetoIdraulico.pdf
  13. quickitaly.com/en/products/windlasses-and-capstans/switches/foot-switches/
  14. quickitaly.com/resources/downloads_qne-prod/1/MOD.900%20REV007A.pdf
  15. quickitaly.com/resources/downloads_qne-prod/1/HRC100x_Rev05D.pdf
  16. jimmygreen.com/product/quick-osp-pressure-lever-kits/

Quick is a trademark of its owner; boatparts.app is not affiliated with it. Part numbers are quoted for identification only. Spotted an error? Write to mail@boatparts.app.

boatparts.app

The marketplace that speaks boat.

@boatparts.app Facebook
  • Manuals
  • Contact
  • Press kit
  • Partners
  • Legal notice
  • Privacy Policy
  • Terms of Service
  • Report content
  • Delete account
© 2026 Thumanns LLC Map data © OpenStreetMap contributors · Tiles © CARTO